PLA-RP SERIES

Series
Catalogue
Add to Cart Add to cart

Features

3D Sensor

Auto Fan Speed Mode

Auto Restart

Bacteria & Mold-resistant Filter

Long life Filter

Self-Diagnostic Function

Technical Specifications

Models   PLA-RP50EA-DA PLA-RP71EA-DA PLA-RP100EA-DA PLA-RP140EA-DA
Cooling Cooling Capacity - Rated (Min-Max) kW 5.5(2.3-5.6) 7.1(2.8-8.1) 9.4(3.7-10.6) 13.6 (5.8-14.1)
Total Input kW 1.61 2.1 3.18 5.3
ISEER W/W 4.5 4.51 4.4 3.7
Heating Cooling Capacity - Rated (Min-Max) kW 5.8(1.7-7.2) 8.0 (2.6-10.2) 11.2 (2.8-12.5) 15.0(4.9-15.8)
Total Input kW 1.69 2.24 3.26 4.67
COP W/W 3.43 3.56 3.43 3.21
Indoor Unit Model name PLA-RP50EA-DA PLA-RP71EA-DA PLA-RP100EA-DA PLA-RP140EA-DA
Power supply 1Phase 220-240V 50Hz 1Phase 220-240V 50Hz 1Phase 220-240V 50Hz 1Phase 220-240V 50Hz
External finish Munsell 1.0Y 9.2/0.2 Munsell 1.0Y 9.2/0.2 Munsell 1.0Y 9.2/0.2 Munsell 1.0Y 9.2/0.2
Airflow (low-med1-med2-high)   CFM 495-565-600-635 565-600-670-740 670-810-920-1025 850-920-1025-1130
External static pressure Pa 0 (direct blow) 0 (direct blow) 0 (direct blow) 0 (direct blow)
Operation control and thermostat Cordelss Remote control & Built-in
Noise level (low-med1-med2-high) dB (A) 27-29-31-32 28-30-32-34 31-34-37-40 36-39-42-44
Unit drain pipe (outer diameter) mm 32 32 32 32
Dimensions (panel) W mm 840(950) 840(950) 840(950) 840(950)
D mm 840(950) 840(950) 840(950) 840(950)
H mm 258 (40) 258 (40) 298(40) 298(40)
Weight (panel) kg 19(5) 21(5) 24(5) 27(5)
Outdoor Unit Model name SUZ-KA50VA-DA SUZ-KA71VA-DA PUHZ-P100YKA PUHZ-P140YKA
Power supply 1Phase 220-240V 50Hz 3Phase 380-415V 50Hz
External finish Munsell 3.0Y 7.8/1.1
Refrigerant (R410A) control Linear Expansion Valve
Airflow CFM 1575 1770 2792 3039
Noise Level dB (A) 52 55 51 56
Dimensions W mm 840 840 1050 1050
D mm 330 330 330(+25) 330(+25)
H mm 880 880 981 981
Weight kg 54 53 78 85
Max. height difference m 30 30 30 30
Max. piping length m 30 30 50 50
Pipe size Liquid mm 6.35 9.52 9.52 9.52
Gas mm 12.7 15.88 15.88 15.88
BEE Star Rating 3 3 3 3
Cooling Guaranteed Operating Range Upper limit (CDB) 46 46 46 46
Lower limit (CDB) -15 -15 -15 -15
Heating Guaranteed Operating Range Upper limit (CDB) 24 24 21 21
Lower limit (CDB) -10 -10 -15 -15
        MRP 121690 147230 188700 244010

 

•Rating conditions: Cooling - Indoor: 27°C (DST), 19°C , Outdoor: 35°C (DBT)                                
•Rating conditions Cooling - Indoor: 27°C(80°F)DB,19°C(66°F)W13. Outdoor: 35°C(95°F)DB                                
•Refrigerant piping length (one-way): 7.5m(2511)                                
- Total input based on the indicated voltage (indoor/outdoor): 1 ph 230V 50Hz, 3ph 400V 50Hz                                
- The sound pressure meaurement is conducted in an anechoic chamber under the test conditions of Japanese industrial Standards.                                
•The actual sound level depends on the design and appropriate set up of duct work, distance from the unit and acoustic environment                                 
- Measured with a 2.Om. Air outlet duct and 1.0m. Air inlet duct attached Measured point 1.5m. Below the unit.                                
•Rated external static pressure mode is shown with < >.                                
 